arrow-red.gif (255 bytes)Materials Spec.

arrow-red.gif (255 bytes)Installation

arrow-red.gif (255 bytes) Architectural Spec.

arrow-red.gif (255 bytes)Loading test

Conceal Ceiling Installation Pattern

Conceal Ceiling Suspension System is suitable for fixing all kinds of ceiling finishes e.g. Gypsum Board, Villboard ( Fibre Reinforced Cement Board) , Plywood and mineral Fibre Board etc.

According to the weight and size of the board, some of the members shall adjust the spacing to suit.

The following ceiling pattern with uniformly distributed load are recommended for installation.

hd-11.jpg (39890 bytes)

Note:

1. Incorporates a factor of safety of 1.6  for the following table.

2. The deflection limited of L/240 of the span ( ASTM C645 )

3. For external soffit application to resist wind loads, please contact to our office for further information

Pattern

Uniformly Distributed

A 25 kg/m2
B 60 kg/m2

   Click for Ceiling Installation drawing