Loading Test Data Based on ASTM C635 1/360 Span Deflection
Product |
Item Code | Length | Height in (mm) | Load Carrying Capacity (kg/m) |
Main Tee |
Ms-10' | 10' | 32 | 9.9 |
Cross Tee |
CS-2' | 2' | 26.5 | 37.7 |
| CS-4' | 4' | 26.5 | 6.0 | |
| CS-500 | 500 mm | 26.5 | 75.7 | |
| CS-1000 | 1000 mm | 26.5 | 10.5 | |
| CS-625 | 625 mm | 26.5 | 38.4 | |
| CS-1250 | 1250 mm | 26.5 | 5.9 |
¡@
Permissible Distributed Load of Ceiling Grid System
| S/N | Ceiling Modules |
Main Tee Spacing |
Cross Tee Length |
System Components |
Permissible Distributed Load (kg/m2) |
| 1 |
|
4 ft | 4 ft | MS-10' CS-4' |
8.1 |
| 2 |
|
4 ft | 4 ft 2 ft |
MS-10' CS-4' CS-2' |
8.1 |
| 3 |
|
2 ft | 2 ft | MS-10' CS-4' |
16.2 |
| 4 |
|
2 ft | 2 ft | MS-10' CS-4' |
16.2 |
| 5 |
|
4 ft | 4 ft 4 ft |
MS-10' CS-4' CS-2' |
4.9 |
| 6 |
|
4 ft | 4 ft 4 ft 2 ft |
MS-10' CS-4' CS-2' |
4.9 |
| 7 |
|
1000 mm | 1000 mm 500 mm |
MS-3000 CS-1000 CS-500 |
9.9 |
| 8 |
|
500 mm | 500 mm | MS-3000 CS-1000 |
19.8 |
| 9 |
|
1250 mm | 1250 mm 625 mm |
MS-3125 CS-1250 CS-625 |
7.9 |
| 10 |
|
625 mm | 625 mm | MS-3125 CS-625 |
15.8 |
Note:
- For Module 2,5-7 & 9, it was assumed that the second cross tee lying parallel to the main tee is not support any load, but only served as a stiffener to prevent bucking.
Telephone :
(852) 2763 0048 Fax : (852) 2353 5722